Gst60g Echelon Endopath Reload For Hospital Gst60g Echelon Endopath Reload For Hospital
Gst60g Echelon Endopath Reload For Hospital
Gst60g Echelon Endopath Reload For Hospital

Gst60g Echelon Endopath Reload For Hospital

101.20 USD ($)/Piece

Product Details:

  • Usage Type Single-Use, Disposable
  • Instruments Type Laparoscopic Stapler Reload
  • Function Endoscopic tissue transection and resection
  • Features Gripping Surface Technology for tissue control, Consistent staple formation, Single Use
  • Shelf Life 5 Years
  • Measurement Range Tissue thickness 1.75 mm - 2.25 mm
  • Storage Instructions Store in a cool, dry place away from sunlight
  • Click to View more
X

Gst60g Echelon Endopath Reload For Hospital Price And Quantity

  • 1000 Piece
  • 101.20 USD ($)/Piece

Gst60g Echelon Endopath Reload For Hospital Product Specifications

  • Model-specific; Compact Design
  • Advanced Stapling Technology
  • High Staple Precision
  • Green (GST60G)
  • Store in a cool, dry place away from sunlight
  • Reload Cartridges for Surgical Stapler
  • No
  • Manual
  • Endoscopic tissue transection and resection
  • Tissue thickness 1.75 mm - 2.25 mm
  • Silent Operation
  • Lightweight
  • Yes
  • 5 Years
  • Gripping Surface Technology for tissue control, Consistent staple formation, Single Use
  • New
  • Yes
  • Hospital, Laparoscopic Surgery
  • Medical-grade plastic and stainless steel
  • Single-Use, Disposable
  • Laparoscopic Stapler Reload

Gst60g Echelon Endopath Reload For Hospital Trade Information

  • Telegraphic Transfer (T/T)
  • 10000 Piece Per Day
  • 10 Days
  • Sample costs shipping and taxes has to be paid by the buyer
  • Box Packaging
  • Asia, Eastern Europe, Western Europe, Middle East, Africa
  • All India
  • COA

Product Description

Gst60g Echelon Endopath Reload for Hospital

Control Tissue Slippage During Firing

4x less tissue slippage for the most precise transection. Uniquely designed for better grip to provide the least tissue slippage for the most precise
transection. Proprietary Gripping Surface Technology provides superior tissue grip without additional trauma during firing. This means you can transect
more of the tissue you intended - especially in very thick tissue - with each firing.



Consistent Staple Precision for Surgical Excellence

The Echelon Endopath GST60G reload guarantees optimal staple formation across a range of tissue thicknesses (1.75 mm 2.25 mm). Its gripping surface technology minimizes tissue slippage, providing surgeons with excellent control, and supports positive surgical outcomes in both open and minimally invasive procedures, offering safety and consistency during every use.


Designed for Versatility and Reliability

Compatible exclusively with Echelon Flex Powered Staplers, this reload is an essential tool in general, bariatric, thoracic, and colorectal surgeries. Its compact, lightweight design ensures portability and ease of use in various hospital settings, while the single-use disposable format reduces infection risks and upholds stringent hygiene standards.

FAQs of Gst60g Echelon Endopath Reload For Hospital:


Q: How do I properly use the Echelon Endopath GST60G reload during surgery?

A: The GST60G reload is designed for straightforward attachment to Echelon Flex Powered Staplers. Ensure the reload is securely locked into the stapler before proceeding with endoscopic tissue transection or resection. Always follow standard aseptic techniques, as the cartridge is sterile and intended for single-use only.

Q: What types of surgical procedures can the GST60G reload be used for?

A: The GST60G reload is specifically engineered for general, bariatric, thoracic, and colorectal surgeries, and is suitable for both open and laparoscopic approaches where medium to thick tissue requires stapling.

Q: When should I choose the green (GST60G) reload over other reload types?

A: Select the green GST60G reload when encountering medium or thick tissue, as it is calibrated for tissue thickness between 1.75 mm and 2.25 mm. Using the appropriate reload color enhances staple formation and minimizes complications.

Q: Where should the GST60G reload be stored before use?

A: Store the GST60G reload in a cool, dry area away from direct sunlight. Proper storage ensures its sterility is maintained throughout its five-year shelf life and preserves the integrity of its advanced stapling technology.

Q: What is the benefit of the gripping surface technology in this reload?

A: Gripping surface technology is specially designed to provide improved tissue control by minimizing slippage during stapling. This helps surgeons achieve more accurate and consistent staple formation, leading to enhanced patient outcomes.

Q: Is the GST60G reload suitable for use in all hospital environments?

A: Yes, the GST60G reload is engineered for hospital applications, including laparoscopic operating rooms. Its silent operation, compact design, and portable nature make it adaptable for various surgical settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Dialysis Solution' category



Back to top